HOW TO MAKE YOUR OWN CAT 5 TWISTED-PAIR NETWORK CABLES
INTRODUCTION.
The purpose of this article is to show you how to make the two kinds of cables
which can be used to network two or more computers together to form quick and
simple home or small office local area networks (LANs). These
instructions can also be used to make patch cables for networks with more
complex infrastructure wiring.
The two most common unshielded twisted-pair (UTP) network standards are the10
Mhz 10BASE-T Ethernet and the 100Mhz 100BASE-TX Fast Ethernet. The 100BASE-T
standard is quickly becoming the predominant LAN standard. If you are starting
from scratch, to build a small home or office network, this is clearly the
standard you should choose. This article will show you how to make cables which
will work with both standards.
LANS SIMPLIFIED.
A LAN can be as simple as two computers, each having a network interface card
(NIC) or network adapter and running network software, connected together with
a crossover cable.
The next step up would be a network consisting of three or more computers and
a hub. Each of the computers is plugged into the hub with a
straight-thru cable (the crossover function is performed by
the hub).
NETWORK CABLE AND CONNECTORS
There are several classifications of cable used for twisted-pair networks. I'll
skip right over them and state that I use and recommend Category 5 (or CAT 5)
cable for all new installations. Likewise, there are several fire code
classifications for the outer insulation of CAT 5 cable. I use CMR cable,
or "riser cable," for most of the wiring I do. You should also
be aware of CMP or plenum cable (a plenum is used to distribute air in a
building). You may be required by local, state or national codes to use
the more expensive plenum-jacketed cable if it runs through suspended ceilings,
ducts, or other areas, if they are used to circulate air or act as an air
passage from one room to another. If in doubt, use plenum. CMR cable is
generally acceptable for all applications not requiring plenum cable.
CAT 5 wire is available in reel-in-box packaging. This is very handy for
pulling the wire without putting twists in it. Without this kind of package or
a cable reel stand, pulling wire is a two-person job. Before the advent of the
reel-in-box, we used to put a reel of wire on a broom handle to pull it.
One person would hold the broom handle and the other would pull and measure the
cable. You will produce a tangled mess, if you pull the wire off the end of the
reel.
Stranded wire patch cables are often specified for cable segments running from
a wall jack to a PC and for patch panels. They are more flexible than solid
core wire. However, the rational for using it is that the constant flexing of
patch cables may wear-out solid core cable--break it. I don't think this is a
real concern in the average small network. For example, I have one solid core
cable going to my work bench. It has probably flexed and average person's
lifetime of flexes from the many many times I have connected customer computers
to my network. Also, stranded cable is susceptible to degradation from
moisture infiltration, may use an alternate color code, and should not be used
for cables longer than 3 Meters (about 10 feet).
Most of the wiring I do simply connects computers directly
to other computers or hubs. Solid core cable is quite suitable for this
purpose and for many home and small business networks. I find it
also quite acceptable for use as patch cables. You might consider a
stranded wire patch cable if you have a notebook computer you are constantly
moving around.
CAT 5 cable has four twisted pairs of wire for a
total of eight individually insulated wires. Each pair is color
coded with one wire having a solid color (blue, orange, green, or brown) twisted
around a second wire with a white background and a stripe of the same
color. The solid colors may have a white stripe in some
cables. Cable colors are commonly described using the background color
followed by the color of the stripe; e.g., white-orange is a cable with a white
background and an orange stripe.
CONNECTORS.
The straight through and cross-over patch cables discussed in
this article are terminated with CAT 5 RJ-45 modular plugs. RJ-45 plugs
are similar to those you'll see on the end of your telephone cable except they
have eight versus four or six contacts on the end of the plug and they are about
twice as big. Make sure they are rated for CAT 5 wiring. (RJ means
"Registered Jack"). Also, there are RJ-45 plugs designed for
both solid core wire and stranded wire. Others are designed specifically
for one kind of wire or the other. Be sure you buy plugs appropriate
for the wire you are going to use. I use plugs designed to accommodate
both kinds of wire.
NETWORK CABLE TOOLS
Modular Plug Crimp Tool.
You will need a modular crimp tool. This one is very similar to the one I have
been using for many years for all kinds of
telephone cable work and it works just fine for Ethernet cables. You don't
need a lot of bells and whistles, just a tool which will securely crimp RJ-45
connectors. This one is made by
Eclipse Enterprises, Inc.
Even though the crimper has cutters which can be
used to cut the cable and individual wires, and possibly stripping the outer
jacket, I find that the following tools are better for stripping and
cutting the cable...
Universal UTP Stripping Tool (Eclipse).
I recently bought one of these tools and it works slick, and it makes a much
neater cut. I recommend that you purchase one if you will be making many
cables.
Diagonal Cutters
("4 to 6"). It is easier to use diagonal
cutters ("diags" or "dikes") to cut the cable off at the
reel and to fine tune the cable ends during assembly. Also, if you don't
have a stripper, you can strip the cable by using a small knife (X-acto,
utility, etc.) to carefully slice the outer jacket longitudinally and use
the diags to cut it off around the circumference.
A
LITTLE
THEORY
Now, bear with me, you need to understand some of this stuff...
The 10BASE-T and 100BASE-TX Ethernets consist of two
transmission lines. Each transmission line is a pair of twisted
wires. One pair receives data signals and the other pair transmits data
signals. A balanced line driver or transmitter is at one end of one of
these lines and a line receiver is at the other end. A (much) simplified
schematic for one of these lines and its transmitter and receiver follow:
Pulses of energy travel down the transmission
line at about the speed of light (186,000 miles/second). The principal
components of one of these pulses of energy is the voltage potential between
wires and current flowing near the surface of the wires. This energy can
also be considered as residing in the magnetic field which surrounds the wires
and the electric field between the wires. In other words, an
electromagnetic wave which is guided by, and travels down the wires.
The main concern is the transient magnetic fields which
surrounds the wires and the magnetic fields generated externally by the other
transmission lines in the cable, other network cables, electric motors,
fluorescent lights, telephone and electric lines, lightning, etc. This is known
as noise. Magnetic fields induce their own pulses in a transmission
line which may literally bury the Ethernet pulses, the conveyor of the
information being sent down the line.
The twisted-pair Ethernet employs two principle means for
combating noise. The first is the use of balanced transmitters and
receivers. A signal pulse actually consists of two simultaneous pulses
relative to ground: a negative pulse on one line and a positive pulse on the
other. The receiver detects the total difference between these two
pulses. Since a pulse of noise (shown in red in the diagram) usually
produces pulses of the same polarity on both lines one pulse is essentially
canceled by out the other at the receiver. Also, the magnetic field
surrounding one wire from a signal pulse is a mirror of the one on the other
wire. At a very short distance from the two wires the magnetic fields are
opposite and have a tendency to cancel the effect of each other out. This
reduces the line's impact on the other pair of wires and the rest of the world.
The second and the primary means of reducing crosstalk--the
term crosstalk came from the ability to (over) hear conversations on other lines
on your phone--between the pairs in the cable, is the double helix configuration
produced by twisting the wires together. This configuration produces
symmetrical (identical) noise signals in each wire. Ideally, their
difference, as detected at the receiver, is zero. In actuality it is much
reduced.
COLOR-CODE STANDARDS
Again, please bear with me... Let's start with
simple pin-out diagrams of the two types of UTP Ethernet cables and watch how
committees can make a can of worms out of them. Here are the diagrams:
Note that the TX (transmitter) pins are
connected to corresponding RX (receiver) pins, plus to plus and minus to
minus. And that you must use a cossover cable to connect units with
identical interfaces. If you use a straight-through cable, one of the two
units must, in effect, perform the cross-over function.
Two wire color-code standards apply: EIA/TIA 568A and EIA/TIA
568B. The codes are commonly depicted with RJ-45 jacks as follows:
If we apply the 586A color code and show all eight wires,
our pin-out looks like this:
Note that pins 4, 5, 7, and 8 and the blue and brown pairs
are not used in either standard. Quite contrary to what you may read
elsewhere, these pins and wires are not used or required to implement 100BASE-TX
duplexing--they are just plain wasted.
However, the actual cables are not physically that
simple. In the diagrams, the orange pair of wires are not adjacent.
The blue pair is upside-down. The right ends match RJ-45 jacks and the
left ends do not. If, for example, we invert the left side of the 586A
"straight"-thru cable to match a 586A jack--put one 180╟ twist in the
entire cable from end-to-end--and twist together and rearrange the appropriate
pairs, we get the following can-of-worms:
This further emphasizes, I hope, the importance of the word "twist"
in making network cables which will work. You cannot use an flat-untwisted
telephone cable for a network cable. Furthermore, you must use a pair of
twisted wires to connect a set of transmitter pins to their corresponding
receiver pins. You cannot use a wire from one pair and another wire from a
different pair.
Keeping the above principles in mind, we can
simplify the diagram for a 568A straight-thru cable by untwisting the
wires, except the 180╟ twist in the entire cable, and bending the ends
upward. Likewise, if we exchange the green and orange pairs in the 568A
diagram we will get a simplified diagram for a 568B straight-thru cable.
If we cross the green and orange pairs in the 568A diagram we will arrive at a
simplified diagram for a crossover cable. All three are shown below.
LET'S MAKE IT SIMPLER
There are only two unique cable ends in the
preceding diagrams. They correspond to the 568A and 568B RJ-45 jacks and are
shown to the right.
Again, the wires with colored
backgrounds may have white stripes and may be donated that way in diagrams found
elsewhere. For example, the green wire may be labeled Green-White--I don't
bother. The background color is always specified first.
Now, all you need to remember, to properly
configure the cables, are the diagrams for the two cable ends and the following
rules:
It makes no functional difference which
standard you use for a straight-thru cable. You can start a
crossover cable with either standard as long as the other endis the other
standard. It makes no functional difference which end is which.
Despite what you may have read elsewhere, a 568A patch cable will work in a
network with 568B wiring and 568B patch cable will work in a 568A network.
The electrons couldn't care less.
My preference is to use the 568A standard for straight-thru cables and to start crossover cables with a 568A
end. That way all I have to remember is the diagram for the 568A end, that
a straight-thru cable has two of them, and that the green and orange pairs are
swapped at the other end of a crossover cable.
LET'S MAKE SOME CABLES
1. Pull the cable off the reel to the
desired length and cut. I have a box of cable at one end of my shop and a
mark on the floor 10' away. For cable lengths which are a fraction
of ten feet, I eye-ball the length as I pull the cable out of
the box (also, my feet are about one foot long). For longer cables, I pull
it out to the ten foot mark and go back to the box and pull the remaining
fraction or another ten feet. If you are pulling cables through walls, a
hole in the floor, etc., it easier to attach the RJ-45 plugs after the cable is
pulled. The total length of wire segments between a PC and a hub or
between two PC's cannot exceed 100 Meters (328 feet or about the length of a
football field) for 100BASE-TX and 300 Meters for 10BASE-T.
2. Strip one end of the cable with the stripper or a knife and diags. If you
are using the stripper, place the cable in the groove on the blade (left) side
of the stripper and align the end of the cable with the right side of the
stripper. This will strip about 1/2" of the jacket off the
cable. Turn the stripper about 1 1/4 turns and pull. If you turn it
more, you will probably nick the wires. If you are using a knife and diags,
carefully slit the cable for about an inch or so and neatly trim around the
circumference of the cable with diags to remove the jacket.
3. Inspect the wires for
nicks. Cut off the end and start over if you see any. You may
have to adjust the blade with the screw at the front stripper. Cable
diameters and jacket thicknesses vary.
4. Spread and arrange the pairs roughly in the order of the desired cable end.
5. Untwist the pairs and arrange the
wires in the order of the desired cable end. Flatten the end between your
thumb and forefinger. Trim the ends of the wires so they are even with one
another.
It is very important that the unstripped (untwisted) end
be slightly less than 1/2" long.
If it is longer than 1/2" it will be out-of-spec and susceptible to crosstalk.
If it less than slightly less than 1/2" it will not be properly
clinched when RJ-45 plug is crimped on. Flatten again. There should
be little or no space between the wires.
6. Hold the RJ-45 plug with the clip facing down or away from you. Push the
wire firmly into the plug. Now, inspect the darn
thing... before crimping and wasting the plug! Looking through
the bottom of the plug, the wire on the far left side will have a white
background. The wires should alternate light and dark from left to
right. The furthest right wire is brown. The wires should all end
evenly at the front of the plug. The jacket should end just about where
you see it in the diagram--right on the line. Aren't you glad you didn't
crimp the plug?
ALL ABOUT CRIMPING
7. Hold the wire near the RJ-45 plug
with the clip down and firmly push it into the left side of the front of the
crimper (it will only go in one way). Hold the wire in place squeeze the
crimper handles quite firmly. This is what will happen:
(Crimp it once.) The crimper pushes two plungers
down on the RJ-45 plug. One forces what amounts to a cleverly designed
plastic plug/wedge onto the cable jacket and very firmly clinches it. The
other seats the "pins," each with two teeth at its end, through the
insulation and into the conductors of their respective wires.
8. Test the crimp... If done properly an average
person will not be able to pull the plug off the cable with his or her bare
hands. And that quite simply, besides lower cost, is the primary advantage
of twisted-pair cables over the older thinwire, coaxial cables. In fact, I
would say the RJ-45 and ease of its installation is the main reason
coaxial cable is no longer widely used for small Ethernets. But, don't
pull that hard on the plug. It could stretch the cable and change its
characteristics. Look at the side of the plug and see if it looks like the
diagram and give it a fairly firm tug to make sure it is crimped well.
9. Prepare the other end of the cable so it has the
desired end and crimp.
10. If both ends of the cable are within reach, hold
them next to each other and with RJ-45 clips facing away. Look through the
bottom of the plugs. If the plugs are wired correctly, and they are
identical, it is a straight-thru cable. If they are wired correctly and
they are different, it is a crossover cable.
11. If you have an operational network, test the
cable. Copy some large files.
12. If the cable doesn't work, inspect the ends
again and make sure you have the right cable and that it is plugged into the
correct units for the type of cable. Try power-cycling (cold booting) the
involved computers.
13. If you have many straight-thru cables and a
crossover cable in your system, you should consider labeling the crossover cable
or using a different colored cable for the crossover cable so you don't mix them
up. I do not recommend implementing the crossover function, as recommended
elsewhere, with two RJ-45 jacks, appropriately wired back to back, and two
straight-thru cables. This method costs noticeably more, introduces more
than the necessary number of components and connections, increases the
complexity and time of assembly, and decreases reliability.
CABLING RULES
1. Try to avoid running cables parallel to power cables.
2. Do not bend cables to less than four times the diameter of the cable.
3. If you bundle a group of cables together with cable ties (zip ties), do not over-cinch them. It's okay to snug them together firmly; but don't tighten them so much that you deform the cables.
4. Keep cables away from devices which can introduce noise into them. Here's a short list: copy machines, electric heaters, speakers, printers, TV sets, fluorescent lights, copiers, welding machines, microwave ovens, telephones, fans, elevators motors, electric ovens, dryers, washing machines, and shop equipment.
5. Avoid stretching UTP cables (the force should not exceed 25 LBS).
6. Do not run UTP cable outside of a building. It presents a very dangerous lightning hazard!
7. Do not use a stapler to secure UTP cables. Use telephone wire hangers which are available at most hardware stores.
Larry
REFERENCES
David Hess and John Gold; A Practical Guide to Cable Selection, National Semiconductor Application Note 916, 0ctober 1993
(http://www.national.com/an/AN/AN-916.pdf)
Keneth M. True; Data Transmission Lines and Their Characteristics,, National Semiconductor Application Note 806, April 1992
(http://www.national.com/an/AN/AN-806.pdf)
Hubbell Premise Wiring
(http://www.hubbell-premise.com/)
ConnectWorld Cable FAQ
(http://www.connectworld.net/cables/cablefaq.html)
Charles Spurgeon's Ethernet Web Site
(http://wwwhost.ots.utexas.edu/ethernet/ethernet-home.html)
Robert Grover Brown, et al; Lines, Waves, and Antennas, The Transmission of Electrical Energy, The Ronald Press Company, New York, 1973
 |